Programming
AC-F/G4x Family Installation and Programming Manual 35
Table 3: Quick Reference Guide for Auxiliary Mode Setting
Auxiliary
Mode
Auxiliary Input
Function
Auxiliary Output Activated
by
Auxiliary
Relay
Auxiliary Settings (in seconds)
0 AUX REX Valid code or AUX REX N.O. 01 to 99 Aux. Relay Release Time
00 Aux. relay toggle
1 Normal/Secure switch Valid code N.O. 01 to 99 Aux. Relay Release Time
00 Aux. relay toggle
2 Normal/Secure switch
Star button (*)
N.O. 01 to 99 Aux. Relay Release Time
00 Aux. relay toggle
3 Normal/Secure switch Tamper event N.C. 01 to 99 Aux. Relay Release Time
00 Aux. relay tamper activated
4 Normal/Secure switch Direct shunt N.O. 01 to 99 Shunt time
5 Door Monitor Shunt N.C. 01 to 99 maximum Shunt time
6 Door Monitor Forced door N.C. 01 to 99 Forced delay
7 Door Monitor Door ajar N.C. 01 to 99 Ajar delay
8 LED control – Green Valid code N.O. 01 to 99 Aux. Relay Release time
00 Aux. relay toggle
9 LED controlRed Valid code N.O. 01 to 99 Aux. Relay Release time
00 Aux. relay toggle
Przeglądanie stron 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 51 52

Komentarze do niniejszej Instrukcji

Brak uwag