AS-215 PC management software
Page 27
Panel Input General Tab has the following fields:
Field Description
Description
Type in the relevant description for the input
Input Function
General Purpose only
Type (active for
supervised only)
Select between:
Normally Open
Normally open (with) 1 resistor
Normally open (with) 2 resistors
Bell (Input 2A
Closed)
This field defines that a chime type alarm is sounded in the
following Input 2A closed
8. Double click on Alarm Output. The output dialog box opens.
Alarm Output - General Tab
This tab is used to define how this output will be activated.
Alarm Output General Tab has the following fields:
Field Description
Description
Type in the relevant description for the input
Operation mode
This field has the following options:
None: Output is inactive
Door held open alert: When selected, the output is activated in the
door held open alert condition
Door held open: When selected, the output is activate in the
door held open condition
Door forced open: When selected, the output is activate in the door
forced condition
Door Tamper & trouble: When selected, the output is activate during
reader tamper and trouble conditions
All door alarms: When selected, the output is activate in any of the
above alarm conditions
Automatic operation: When selected the output is activated by the
fields of the Automatic operation below